<div class="xblock xblock-public_view xblock-public_view-vertical" data-course-id="course-v1:Profosvita+CS-K004SFPL+2024" data-init="VerticalStudentView" data-runtime-class="LmsRuntime" data-runtime-version="1" data-block-type="vertical" data-usage-id="block-v1:Profosvita+CS-K004SFPL+2024+type@vertical+block@d1972980dc4d45328841c56c52141913" data-request-token="1d3dddde2e9b11f0b8322a5492892f60" data-graded="False" data-has-score="False">
<div class="vert-mod">
<div class="vert vert-0" data-id="block-v1:Profosvita+CS-K004SFPL+2024+type@html+block@48a1caf6eb4643b199f95aa71ae3ea8c">
<div class="xblock xblock-public_view xblock-public_view-html xmodule_display xmodule_HtmlBlock" data-course-id="course-v1:Profosvita+CS-K004SFPL+2024" data-init="XBlockToXModuleShim" data-runtime-class="LmsRuntime" data-runtime-version="1" data-block-type="html" data-usage-id="block-v1:Profosvita+CS-K004SFPL+2024+type@html+block@48a1caf6eb4643b199f95aa71ae3ea8c" data-request-token="1d3dddde2e9b11f0b8322a5492892f60" data-graded="False" data-has-score="False">
<script type="json/xblock-args" class="xblock-json-init-args">
{"xmodule-type": "HTMLModule"}
</script>
<p style="text-align: center;"></p>
<p>Демонтаж є одним із елементів технологічного процесу, пов’язаного з оновленням, ремонтом або заміною трансформаторів. Правильний спосіб його виконання повинен бути описаний в техніко-експлуатаційній документації (ТЕД), що надається виробником разом з машиною. Документація повинна складатися з встановлених форм, які детально описують окремі фази, операції та процедури цього процесу. Основним правилом виконання робіт, пов'язаних з демонтажем трансформаторів, є абсолютна необхідність їх знеструмлення. З огляду на різноманітність, призначення та потужність трансформаторів існують різні способи і методи їх демонтажу. Процедура демонтажу силового трансформатора на підстанції виглядає інакше, ніж трансформатора, встановленого, наприклад, в електронному пристрої.</p>
<p>Перш ніж приступити до демонтажу трансформатора, необхідно підготувати необхідні інструменти і обладнання:</p>
<ul>
<li>відповідні ключі для відкручування елементів трансформаторного обладнання;</li>
<li>шланги для скидання трансформаторного масла;</li>
<li>ємності для електроізоляційного масла, налитого з трансформаторного чану, яку слід підбирати в залежності від кількості масла в чані, слід пам'ятати, що вага трансформаторного масла може варіюватися від приблизно 120 кг до 1300 кг; </li>
</ul>
<p style="text-align: center;"><span style="text-decoration: underline;"><img src="/assets/courseware/v1/8b9ad8a362b0022abb3d1d72bb813269/asset-v1:Profosvita+CS-K004SFPL+2024+type@asset+block/%D0%9C%D0%BE%D0%B4%D1%83%D0%BB%D1%8C3_%D0%A2%D0%A0%D0%90%D0%9D%D0%A1%D0%A4%D0%9E%D0%A0%D0%9C%D0%90%D0%A2%D0%9E%D0%A0%D0%98__4._%D0%A0%D0%BE%D0%B7%D0%B1%D0%B8%D1%80%D0%B0%D0%BD%D0%BD%D1%8F_%D1%82%D0%B0_%D0%B7%D0%B1%D1%96%D1%80%D0%BA%D0%B0_%D1%82%D1%80%D0%B0%D0%BD%D1%81%D1%84%D0%BE%D1%80%D0%BC%D0%B0%D1%82%D0%BE%D1%80%D1%96%D0%B2_html_b521e48326633a58.jpg" alt="" width="850" height="566" /></span></p>
<p style="text-align: center;"><span style="text-decoration: underline;">Рисунок 4.1 Ємність для використаної трансформаторної олії</span></p>
<ul>
<li>для демонтажу втулок, вентиляторів, масляно-повітряних радіаторів або консерватора через велику вагу може знадобитися кран;</li>
<li>гідравлічні домкрати;</li>
<li>троси для кріплення та кріплення до втулок крана або інших важких елементів трансформаторного обладнання;</li>
<li>контейнери для втулок.</li>
</ul>
<p>Слід пам'ятати, що будь-які роботи, пов'язані з демонтажем силового трансформатора, повинні проводитися в сонячні дні і при низькій вологості повітря. Приклад послідовності дій при демонтажі потужного трансформатора після його попереднього відключення від мережі можна представити наступним чином:</p>
<ul>
<li>зливаємо мінеральне електроізоляційне масло з трансформаторного чану в спеціально підготовлені для цього ємності;</li>
<li>розбираємо встановлені масляно-повітряні охолоджувачі;</li>
</ul>
<p style="text-align: center;"><span style="text-decoration: underline;"><img src="/assets/courseware/v1/d49f9e7f3dff89388be428341207706c/asset-v1:Profosvita+CS-K004SFPL+2024+type@asset+block/%D0%9C%D0%BE%D0%B4%D1%83%D0%BB%D1%8C3_%D0%A2%D0%A0%D0%90%D0%9D%D0%A1%D0%A4%D0%9E%D0%A0%D0%9C%D0%90%D0%A2%D0%9E%D0%A0%D0%98__4._%D0%A0%D0%BE%D0%B7%D0%B1%D0%B8%D1%80%D0%B0%D0%BD%D0%BD%D1%8F_%D1%82%D0%B0_%D0%B7%D0%B1%D1%96%D1%80%D0%BA%D0%B0_%D1%82%D1%80%D0%B0%D0%BD%D1%81%D1%84%D0%BE%D1%80%D0%BC%D0%B0%D1%82%D0%BE%D1%80%D1%96%D0%B2_html_7dc5e582142ffc81.png" alt="" width="688" height="517" /></span></p>
<p style="text-align: center;"><span style="text-decoration: underline;">Рисунок </span><span style="text-decoration-line: underline;">4.</span><span style="text-decoration-line: underline; font-size: 1em;">2 Масляно-повітряні охолоджувачі потужністю 2 325 кВт на трансформаторі типу AISR30-3300000/400PN</span></p>
<ul>
<li>розбираємо втулкові ізолятори – і тут, в залежності від розміру (або ваги) ізоляторів, їх можна демонтувати вручну або у випадку важких ізоляторів – їх слід піднімати відповідними ліфтами. Вага втулки ізолятора вказується на табличці даних, яку перед демонтажем слід очистити, щоб зчитати вагу і відповідно визначитися з наступними кроками;</li>
</ul>
<p style="text-align: center;"><span style="text-decoration: underline;"><img src="/assets/courseware/v1/5af99b7e316aa62c2f09cbb7f82b241a/asset-v1:Profosvita+CS-K004SFPL+2024+type@asset+block/%D0%9C%D0%BE%D0%B4%D1%83%D0%BB%D1%8C3_%D0%A2%D0%A0%D0%90%D0%9D%D0%A1%D0%A4%D0%9E%D0%A0%D0%9C%D0%90%D0%A2%D0%9E%D0%A0%D0%98__4._%D0%A0%D0%BE%D0%B7%D0%B1%D0%B8%D1%80%D0%B0%D0%BD%D0%BD%D1%8F_%D1%82%D0%B0_%D0%B7%D0%B1%D1%96%D1%80%D0%BA%D0%B0_%D1%82%D1%80%D0%B0%D0%BD%D1%81%D1%84%D0%BE%D1%80%D0%BC%D0%B0%D1%82%D0%BE%D1%80%D1%96%D0%B2_html_e633e6b29c9950a5.png" alt="" width="523" height="379" /></span></p>
<p style="text-align: center;"><span style="text-decoration: underline;">Рисунок </span><span style="text-decoration-line: underline;">4.</span><span style="text-decoration-line: underline; font-size: 1em;">3 Втулки, встановлені на трифазний масляний розподільчий трансформатор </span></p>
<ul>
<li>розбираємо систему трубних з'єднань;</li>
<li>демонтуємо двокамерний консерватор, обладнаний індикатором рівня масла та необслуговуваними осушувачами;</li>
</ul>
<p style="text-align: center;"><span style="text-decoration: underline;"><img src="/assets/courseware/v1/8a57cd261735a25bd651965593262f30/asset-v1:Profosvita+CS-K004SFPL+2024+type@asset+block/%D0%9C%D0%BE%D0%B4%D1%83%D0%BB%D1%8C3_%D0%A2%D0%A0%D0%90%D0%9D%D0%A1%D0%A4%D0%9E%D0%A0%D0%9C%D0%90%D0%A2%D0%9E%D0%A0%D0%98__4._%D0%A0%D0%BE%D0%B7%D0%B1%D0%B8%D1%80%D0%B0%D0%BD%D0%BD%D1%8F_%D1%82%D0%B0_%D0%B7%D0%B1%D1%96%D1%80%D0%BA%D0%B0_%D1%82%D1%80%D0%B0%D0%BD%D1%81%D1%84%D0%BE%D1%80%D0%BC%D0%B0%D1%82%D0%BE%D1%80%D1%96%D0%B2_html_ac81437db0c8ac9a.png" alt="" width="688" height="380" /></span></p>
<p style="text-align: center;"><span style="text-decoration: underline;">Рисунок </span><span style="text-decoration-line: underline;">4.</span><span style="text-decoration-line: underline; font-size: 1em;">4 Двокамерний консерватор, встановлений над трансформаторним чаном</span></p>
<ul>
<li>демонтуємо трансформатори струму і, можливо, з`єднання трансформаторів струму;</li>
<li>демонтуємо систему труб, від`єднуючи її від системи охолодження і насоса.</li>
</ul>
<p>Після демонтажу трансформатора його зазвичай здають на ремонт, модернізацію або металобрухт. Якщо трансформатор підлягає модернізації або ремонту, його необхідно транспортувати до місця призначення. Під час транспортування та переміщення рекомендується використовувати відповідні підйомні проушини або спеціальні буксирувальні гаки. Особливу увагу слід приділити тому, щоб під час переміщення трансформатора не натискали його обмоткові котушки або з'єднання цих обмоток.</p>
<p>Усі роботи, пов’язані з розбиранням трансформатора на активній силовій підстанції, слід виконувати при знеструмлених приладах. Слід бути особливо обережними, оскільки роботи будуть проводитися в зоні, неподалік від напруги. Тому місце демонтажу слід відгородити від решти працюючої станції, яка перебуває під напругою таким чином, щоб забезпечити безпеку працівників. У разі виконання робіт, що відносяться до робіт на висоті, повинні застосовуватися чинні вимоги і правила. Особлива увага потрібна для проведення робіт, пов'язаних із використанням, наприклад, самохідного крану або лебідки, оскільки поблизу під напругою можуть знаходитися інші розподільчі пристрої та високовольтні лінії, що проходять через огороджене робоче місце. Перед початком робіт усі виконавці повинні бути проінструктовані стосовно правил робіт та пересування в зоні енергетичних об’єктів, оснащення їх захисним одягом та засобами індивідуального захисту, тобто шоломами, захисними окулярами, рукавичками та всім іншим, що випливає із специфіки виконуваної роботи. Вантажівки, що перевозять демонтований трансформатор та інші елементи демонтажу, повинні пересуватися по станції тільки виключно за відведеними для цієї мети маршрутами. Крім того, ними завжди повинен керувати кваліфікований уповноважений персонал від самих воріт до місця демонтажу. </p>
<p>Якщо демонтований трансформатор не придатний для подальшого використання, або його ремонт чи реконструкція економічно невигідні, то приймається рішення про його утилізацію. Слід пам'ятати, що масляні трансформатори виготовляються з таких матеріалів, як мідь, сталь, ізоляційні матеріали, гума, пластмаси, папір, порцеляна і найнебезпечніший з точки зору захисту навколишнього середовища - масло. При розбиранні та транспортуванні саме цього компонента слід звернути особливу увагу на запобігання витоку та можливого проникнення масла в землю та підземні води. Найкраще довірити цю частину робіт компанії з досвідом і необхідною ліцензією на ведення цього виду діяльності. Після видалення трансформаторного масла з бака трансформатора його слід доставити до місця, де скуповують використане масло. Таке масло не можна спалювати в установках, які не пристосовані до цієї операції та не відповідають відповідним критеріям.</p>
</div>
</div>
</div>
<script type="text/javascript">
(function (require) {
require(['/static/js/dateutil_factory.762fd6ff462b.js?raw'], function () {
require(['js/dateutil_factory'], function (DateUtilFactory) {
DateUtilFactory.transform('.localized-datetime');
});
});
}).call(this, require || RequireJS.require);
</script>
<script>
function emit_event(message) {
parent.postMessage(message, '*');
}
</script>
</div>
<div class="xblock xblock-public_view xblock-public_view-vertical" data-course-id="course-v1:Profosvita+CS-K004SFPL+2024" data-init="VerticalStudentView" data-runtime-class="LmsRuntime" data-runtime-version="1" data-block-type="vertical" data-usage-id="block-v1:Profosvita+CS-K004SFPL+2024+type@vertical+block@a5542d6fdee74665aa1210d29cc4cd21" data-request-token="1d3dddde2e9b11f0b8322a5492892f60" data-graded="False" data-has-score="False">
<div class="vert-mod">
<div class="vert vert-0" data-id="block-v1:Profosvita+CS-K004SFPL+2024+type@html+block@e1b27a623de64efe887eb69955943cb6">
<div class="xblock xblock-public_view xblock-public_view-html xmodule_display xmodule_HtmlBlock" data-course-id="course-v1:Profosvita+CS-K004SFPL+2024" data-init="XBlockToXModuleShim" data-runtime-class="LmsRuntime" data-runtime-version="1" data-block-type="html" data-usage-id="block-v1:Profosvita+CS-K004SFPL+2024+type@html+block@e1b27a623de64efe887eb69955943cb6" data-request-token="1d3dddde2e9b11f0b8322a5492892f60" data-graded="False" data-has-score="False">
<script type="json/xblock-args" class="xblock-json-init-args">
{"xmodule-type": "HTMLModule"}
</script>
<p>Перед тим, як приступити до установки трансформатора на площадці, слід провести його детальний огляд:</p>
<ul>
<li>оглянути трансформатор, зокрема чан,</li>
<li>перевірити технічний стан індикатора рівня масла,</li>
</ul>
<p style="text-align: center;"><img height="323" width="700" src="/assets/courseware/v1/3db3e70d0621f91862ba3c9cc77004ec/asset-v1:Profosvita+CS-K004SFPL+2024+type@asset+block/t1.jpg" alt="" /></p>
<p style="text-align: center;"><span style="text-decoration: underline;">Рисунок </span><span style="text-decoration-line: underline;">4.</span><span style="text-decoration-line: underline; font-size: 1em;">5 Індикатор рівня масла</span></p>
<ul>
<li>перевірити стан втулкових ізоляторів, так як робота з пошкодженою втулкою може бути причиною пошкодження трансформатора.</li>
</ul>
<p style="text-align: center;"><span style="text-decoration: underline;"><img height="540" width="724" src="/assets/courseware/v1/ecbec1945e227fd9f6322779a3412602/asset-v1:Profosvita+CS-K004SFPL+2024+type@asset+block/%D0%9C%D0%BE%D0%B4%D1%83%D0%BB%D1%8C3_%D0%A2%D0%A0%D0%90%D0%9D%D0%A1%D0%A4%D0%9E%D0%A0%D0%9C%D0%90%D0%A2%D0%9E%D0%A0%D0%98__4._%D0%A0%D0%BE%D0%B7%D0%B1%D0%B8%D1%80%D0%B0%D0%BD%D0%BD%D1%8F_%D1%82%D0%B0_%D0%B7%D0%B1%D1%96%D1%80%D0%BA%D0%B0_%D1%82%D1%80%D0%B0%D0%BD%D1%81%D1%84%D0%BE%D1%80%D0%BC%D0%B0%D1%82%D0%BE%D1%80%D1%96%D0%B2_html_1bff411639fc8d7e.png" alt="" /></span></p>
<p style="text-align: center;"><span style="text-decoration: underline;">Рисунок </span><span style="text-decoration-line: underline;">4.</span><span style="text-decoration-line: underline; font-size: 1em;">6 Пропускні ізолятори типу DIN 42531</span></p>
<p>Наведена вище процедура візуального огляду спрямована на перевірку того, чи не сталося витоків масла або механічних пошкоджень в процесі транспортування або зберігання. Крім того:</p>
<ul>
<li>якщо на частинах корпусу трансформатора виявлено пошкоджений лак або фарбу, то такі місця слід захистити від корозії фарбуванням;</li>
<li>перевірити показники поплавкового індикатора і за потреби долити масло;</li>
</ul>
<p style="text-align: center;"><span style="text-decoration: underline;"><img height="700" width="380" src="/assets/courseware/v1/d070dd8a2732ecf292223348e056abee/asset-v1:Profosvita+CS-K004SFPL+2024+type@asset+block/%D0%9C%D0%BE%D0%B4%D1%83%D0%BB%D1%8C3_%D0%A2%D0%A0%D0%90%D0%9D%D0%A1%D0%A4%D0%9E%D0%A0%D0%9C%D0%90%D0%A2%D0%9E%D0%A0%D0%98__4._%D0%A0%D0%BE%D0%B7%D0%B1%D0%B8%D1%80%D0%B0%D0%BD%D0%BD%D1%8F_%D1%82%D0%B0_%D0%B7%D0%B1%D1%96%D1%80%D0%BA%D0%B0_%D1%82%D1%80%D0%B0%D0%BD%D1%81%D1%84%D0%BE%D1%80%D0%BC%D0%B0%D1%82%D0%BE%D1%80%D1%96%D0%B2_html_1e16b06f8db77d9d.png" alt="" /></span></p>
<p style="text-align: center;"><span style="text-decoration: underline;">Рисунок </span><span style="text-decoration-line: underline;">4.</span><span style="text-decoration-line: underline; font-size: 1em;">7 Масляний поплавковий індикатор у мінімальному положенні, нижче такого положення неприпустима робота трансформатора</span></p>
<ul>
<li>перевірити правильність установки проміжків іскри на прохідних ізоляторах (не поширюється на трансформатори, оснащені роз'ємними втулками), ізольований інтервал проміжків іскри в залежності від робочих напруг мережі повинен бути:</li>
</ul>
<p> ◦ до 12 кВ – без виступів</p>
<p> ◦ вище 12 кВ до 17,5 кВ – 90 мм</p>
<p> ◦ вище 17,5 кВ до 24 кВ – 120 мм</p>
<p> ◦ до 25 кВ – 150 мм</p>
<p> ◦ вище 25 кВ до 30 кВ – 200 мм</p>
<p> ◦ до 38,5 кВ – 220 мм</p>
<p>Трансформатор повинен розташовуватися в спеціально призначеному для цього місці. Таке місце, в залежності від конструкції трансформатора, який може бути встановлений на платформах або сталевих конструкціях, підвішених на стовпі або встановлених всередині розподільчої станції, повинно відповідати наступним умовам:</p>
<ul>
<li>основа повинна бути вирівняна, з допустимою похибкою до 3°;</li>
<li>після установки на підставку трансформатор повинен бути зафіксований від переміщення або зміни його положення.</li>
</ul>
<p>При складанні трансформатора на робочому місці слід:</p>
<ul>
<li>заземлити бак трансформатора за допомогою клем заземлення, з'єднання повинно бути надійним і захищене від ослаблення та корозії. Робоче заземлення (нейтральна точка низьковольтної мережі) слід відокремити від захисного заземлення;</li>
<li>виконати підключення верхньої і нижньої напруги. Якщо в трансформаторі використовуються високовольтні вводи з покращеною конструкцією ущільнювача штифтів, то немає необхідності в додатковому блокуванні, оскільки вони блокуються безпосередньо на вводі. Гайки слід затягувати з моментом не більше 15 Нм, тому перед установкою найкраще озброїтися відповідними інструментами. Під’єднання високої та низької напруги повинні бути якомога коротшими та жорсткішими, але виконаними таким чином, щоб вони не чинили розривних зусиль на ізолятори. Вони повинні бути щільно затягнутими і захищені від випадкового ослаблення.</li>
<li>здійснити підключення заземлення до нульової точки мережі низької напруги.</li>
</ul>
<p>Перед введенням трансформатора в експлуатацію необхідно:</p>
<ul>
<li>встановити ключовий перемикач і перемикач напруги (стосується комутаційних трансформаторів) у положення, передбачене для роботи трансформатора. Регулювання слід виконувати в режимі без напруги;</li>
</ul>
<p style="text-align: center;"><img height="274" width="700" src="/assets/courseware/v1/d6223c24fc729b25ec95f71b028a5b55/asset-v1:Profosvita+CS-K004SFPL+2024+type@asset+block/t2.jpg" alt="" /></p>
<p style="text-align: center;"><span style="text-decoration: underline;">Рисунок </span><span style="text-decoration-line: underline;">4.</span><span style="text-decoration-line: underline; font-size: 1em;">8 Головка крану перемикача</span></p>
<ul>
<li>перевірити стійкість робочого і захисного заземлення;</li>
<li>якщо були використані вставки запобіжників, перевірте, чи правильно вони вибрано.</li>
</ul>
<p>Якщо трансформатор призначений для паралельної роботи, то необхідно додатково перевірити, чи виконуються умови для такої роботи:</p>
<ul>
<li>сумісність номінальних первинних і вторинних напруг,</li>
<li>сумісність відводів, на яких працюють трансформатори, призначених для паралельної роботи,</li>
<li>сумісність груп з'єднання і погодинний кут зсуву,</li>
<li>відповідність напруги короткого замикання точності по відношенню до середнього значення</li>
<li>коефіцієнт потужності трансформаторів не повинен перевищувати 3:1.</li>
</ul>
<p>Після перевірки перерахованих вище умов трансформатор можна підключити до мережі. Якщо після включення трансформатора виявляються незвичні симптоми його роботи, такі як:</p>
<ul>
<li>потріскування</li>
<li>булькання</li>
<li>висока інтенсивність звуку,</li>
</ul>
<p>то такий трансформатор повинен бути негайно вимкнений і повинні бути проведені контрольні випробування і вимірювання. Якщо трансформатор вимкнений захистом, його не можна включати знову без детального пояснення причини його відключення та її усунення.</p>
<p>Підводячи підсумок, всі трансформатори, незалежно від того, чи вони нові, старі, відремонтовані або переміщені з інших станцій або зі складських резервів, вони повинні бути піддані післямонтажним випробуванням перед першим вмиканням. Обсяг повних вимірювань і післямонтажних випробувань мережевих трансформаторних вузлів включає:</p>
<ul>
<li>зовнішній візуальний огляд;</li>
<li>вимірювання передач і перевірка групи з'єднань;</li>
<li>вимірювання опору обмоток;</li>
<li>перевірка перемикача виводів під навантаженням;</li>
<li>вимірювання ізоляційної стійкості обмоток;</li>
<li>вимірювання ємності обмотки і коефіцієнта втрат;</li>
<li>вимірювання намагнічених струмів;</li>
<li>вивчення показників ізоляції;</li>
<li>обстеження механічного стану обмоток;</li>
<li>аналіз газів, розчинених в маслі;</li>
<li>вивчення властивостей масла;</li>
<li>визначення вмісту води, розчиненої в маслі;</li>
<li>вимірювання ємності і коефіцієнта втрати втулкових ізоляторів;</li>
<li>вимірювання опору ізоляції сердечника та балки та вимірювання стійкості резисторів заземлюючих пакетів та пучків сердечника;</li>
<li>перевірка обладнання;</li>
<li>перевірка роботи газо-потокового реле;</li>
<li>функціональна перевірка роботи шаф управління, системи охолодження приводу вимикача, індикаторів масляного потоку, клапанів і елементів вимірювання температури трансформаторного блоку;</li>
<li>перевірка вентиляційного отвору трансформаторного блоку, системи охолодження, насосів, втулкових ізоляторів, консерватора, вимикача крана і кремнезему в осушувачах;</li>
<li>перевірка шаф управління на предмет захисту від ураження електричним струмом;</li>
<li>перевірка трансформаторів струму всередині (чанів) трансформаторного агрегату: характеристики намагнічування, полярність, трансформаторна шестерня, опір ізоляції;</li>
<li>перевірка вогкості паперової ізоляції.</li>
</ul>
</div>
</div>
</div>
<script type="text/javascript">
(function (require) {
require(['/static/js/dateutil_factory.762fd6ff462b.js?raw'], function () {
require(['js/dateutil_factory'], function (DateUtilFactory) {
DateUtilFactory.transform('.localized-datetime');
});
});
}).call(this, require || RequireJS.require);
</script>
<script>
function emit_event(message) {
parent.postMessage(message, '*');
}
</script>
</div>
Завершення тесту
У вас залишилися невиконані завдання. Ви впевнені, що хочете завершити тест?
Тестування завершено.
Щоб переглянути результат
перейдіть на сторінку "Прогрес"