<div class="xblock xblock-public_view xblock-public_view-vertical" data-course-id="course-v1:Profosvita+CS-K008SFPL+2024" data-init="VerticalStudentView" data-runtime-class="LmsRuntime" data-runtime-version="1" data-block-type="vertical" data-usage-id="block-v1:Profosvita+CS-K008SFPL+2024+type@vertical+block@35a6269e143f4d67a632417eb69ec7a0" data-request-token="f9ff462e0d4311ef975a325c1f8ecab9" data-graded="False" data-has-score="False">
<div class="vert-mod">
<div class="vert vert-0" data-id="block-v1:Profosvita+CS-K008SFPL+2024+type@html+block@d3d0b68f2b3b4c7a83d6afffd7433072">
<div class="xblock xblock-public_view xblock-public_view-html xmodule_display xmodule_HtmlBlock" data-course-id="course-v1:Profosvita+CS-K008SFPL+2024" data-init="XBlockToXModuleShim" data-runtime-class="LmsRuntime" data-runtime-version="1" data-block-type="html" data-usage-id="block-v1:Profosvita+CS-K008SFPL+2024+type@html+block@d3d0b68f2b3b4c7a83d6afffd7433072" data-request-token="f9ff462e0d4311ef975a325c1f8ecab9" data-graded="False" data-has-score="False">
<script type="json/xblock-args" class="xblock-json-init-args">
{"xmodule-type": "HTMLModule"}
</script>
<p>Автоматичні низьковольтні вимикачі включають:</p>
<ul>
<li><em>автоматичні вимикачі</em> призначені для включення і виключення контурів та електричних пристроїв, в яких можуть текти великі струми, включаючи струми короткого замикання. Характерною особливістю цих пристроїв є помірна механічна і комутаційна довговічність, а також низька номінальна частота з'єднань. У підключеному стані вимикачі залишаються без участі зовнішніх сил завдяки спеціальному замку, випуск механізму блокування якого можна запустити як вручну, так і в результаті активації будь-якого з тригерів. Автоматичні вимикачі обладнані тригерами термобіметалічного перевантаження, що відкривають замок з певною затримкою, а також електромагнітними тригерами короткого замикання, що працюють з власним часом 0,02-0,04 с;</li>
</ul>
<p style="text-align: center;"><span style="text-decoration: underline;"><img height="296" width="530" src="/assets/courseware/v1/eda6d1f8be0b87d0f92d17c5cec159a8/asset-v1:Profosvita+CS-K008SFPL+2024+type@asset+block/%D0%9C%D0%BE%D0%B4%D1%83%D0%BB%D1%8C2_%D0%95%D0%BB%D0%B5%D0%BA%D1%82%D1%80%D0%BE%D0%BE%D0%B1%D0%BB%D0%B0%D0%B4%D0%BD%D0%B0%D0%BD%D0%BD%D1%8F__2._%D0%92%D0%B8%D0%BC%D0%B8%D0%BA%D0%B0%D1%87%D1%96_%D0%BD%D0%B8%D0%B7%D1%8C%D0%BA%D0%BE%D1%97_%D0%BD%D0%B0%D0%BF%D1%80%D1%83%D0%B3%D0%B8_%D1%82%D0%B0_%D0%B4%D0%B6%D0%B5%D1%80%D0%B5%D0%BB%D0%B0_%D1%81%D0%B2%D1%96%D1%82%D0%BB%D0%B0_html_78e7cf0102204a9a.jpg" alt="" /></span></p>
<p style="text-align: center;"><span style="text-decoration: underline;">Рисунок 2.5 Автоматичний вимикач: а) система з'єднання, що показує основні складові компоненти, б) ескіз конструкції, 1-база, 2.3- контакти, 4- камера гасіння, 5- електромагнітний механізм перевантаження, 6- тепловий механізм, 7- котушка низької напруги, 8- замок, 9- привідний важіль, 10- корпус</span></p>
<p><em>Джерело: H. Markiewicz, Instalacje elektryczne, WNT, Warszawa 2003, 91 s.</em></p>
<ul>
<li><em>монтажні перемикач</em>і призначені для контролю і захисту від впливу коротких замикань і перевантажень споживчих монтажних контурів та споживачів електроенергії в побутових господарствах та ін. Вони випускаються для номінальної напруги до 440 В, номінальних струмів до 125 А і струмів відключення до 25 кА, з часовими характеристиками типів В, С і D. Однак найбільш поширеними є автоматичні вимикачі для номінальних струмів до 63 А і струмів відключення не більше 10 кА. Вони виготовляються у вигляді плоского апарату шириною 18 мм однополюсних і багатополюсних, створених шляхом об'єднання декількох однополюсних перемикачів із загальним приводом до всіх полюсів. Ці автоматичні вимикачі можуть замінити запобіжники, які використовуються в системах електропостачання за дотримання умов вибірковості дії захисту від надмірного струму, уможливлюючи швидке підключення контурів після усунення короткого замикання, обмежуючи струми короткого замикання – особливо ефективно в разі виникнення короткого замикання в контурі.</li>
</ul>
<p style="text-align: center;"><span style="text-decoration: underline;"><img height="450" width="600" src="/assets/courseware/v1/7955b6588d9fadd93ad378e67b0ef8c0/asset-v1:Profosvita+CS-K008SFPL+2024+type@asset+block/%D0%9C%D0%BE%D0%B4%D1%83%D0%BB%D1%8C2_%D0%95%D0%BB%D0%B5%D0%BA%D1%82%D1%80%D0%BE%D0%BE%D0%B1%D0%BB%D0%B0%D0%B4%D0%BD%D0%B0%D0%BD%D0%BD%D1%8F__2._%D0%92%D0%B8%D0%BC%D0%B8%D0%BA%D0%B0%D1%87%D1%96_%D0%BD%D0%B8%D0%B7%D1%8C%D0%BA%D0%BE%D1%97_%D0%BD%D0%B0%D0%BF%D1%80%D1%83%D0%B3%D0%B8_%D1%82%D0%B0_%D0%B4%D0%B6%D0%B5%D1%80%D0%B5%D0%BB%D0%B0_%D1%81%D0%B2%D1%96%D1%82%D0%BB%D0%B0_html_da25dfa1f16fff4.jpg" alt="" /></span></p>
<p style="text-align: center;"><span style="text-decoration: underline;">Рисунок 2.6 Монтажний перемикач</span></p>
<p><em>Джерело: http://pl.wikipedia.org/</em></p>
<ul>
<li><em>автоматичні вимикачі двигуна</em> призначені для контролю і захисту від впливу надмірних струмів, а також (завдяки встановленню додаткових роз’єднувачів) від небажаних ефектів, пов'язаних з втратою або значним зниженням напруги живлення, вони захищають від асиметрії навантаження і неповнофазної роботи двигунів. Вони випускаються для номінальної напруги до 690 В і номінальних струмів до 80 А, однак найбільш поширеними є ті, що випускаються для струмів до 40 А. Автоматичні вимикачі можуть оснащуватися тригерами перевантаження і короткого замикання, тільки тригерами перенавантаження або тільки тригерами короткого замикання. Також виробляються вимикачі з тригерами напруги - зниженої або підвищеної, також вони реагують на асиметрію навантаження або неповнофазну роботу. Автоматичні вимикачі встановлюються в схемах, де при нормальній роботі можуть виникати значні перепади, тому їх характеристики часового струму аналогічні характеристикам типу D. Струм відмови таких автоматичних вимикачів становить 1,05 А, струм відключення 1,20 А від струму перевантаження, тому даний тип автоматичних вимикачів більш ефективно, ніж пристрої інших конструкцій захищає електроустановки та обладнання від впливу перевантажень;</li>
</ul>
<p style="text-align: center;"><span style="text-decoration: underline;"><img height="384" width="240" src="/assets/courseware/v1/7dd5528b37f3869a0f240dd7da22865d/asset-v1:Profosvita+CS-K008SFPL+2024+type@asset+block/%D0%9C%D0%BE%D0%B4%D1%83%D0%BB%D1%8C2_%D0%95%D0%BB%D0%B5%D0%BA%D1%82%D1%80%D0%BE%D0%BE%D0%B1%D0%BB%D0%B0%D0%B4%D0%BD%D0%B0%D0%BD%D0%BD%D1%8F__2._%D0%92%D0%B8%D0%BC%D0%B8%D0%BA%D0%B0%D1%87%D1%96_%D0%BD%D0%B8%D0%B7%D1%8C%D0%BA%D0%BE%D1%97_%D0%BD%D0%B0%D0%BF%D1%80%D1%83%D0%B3%D0%B8_%D1%82%D0%B0_%D0%B4%D0%B6%D0%B5%D1%80%D0%B5%D0%BB%D0%B0_%D1%81%D0%B2%D1%96%D1%82%D0%BB%D0%B0_html_26fecc3ac47ec60e.jpg" alt="" /></span></p>
<p style="text-align: center;"><span style="text-decoration: underline;">Рисунок 2.7 Автоматичний вимикач двигуна</span></p>
<p><em>Джерело: http://www.tme.eu/pl/katalog/wylaczniki-silnikowe_100413/</em></p>
<ul>
<li><em>автоматичні вимикачі залишкового струму</em>, їх основним елементом є підсумовуючий трансформатор. При однаковій кількості витків фазових витків і нейтральних проводів, намотаних на серцевину трансформатора або тих, що проходять через вікно трансформатора, геометрична сума струмів, потоку і магнітного потоку, що виробляються цими струмами, дорівнюють нулю: <img src="data:image/png;base64,iVBORw0KGgoAAAANSUhEUgAAABEAAAATCAYAAAB2pebxAAABEElEQVR4nOWUMW6DMBSGfySOgpeqJ4ATBHav2ehoH4CxBwhjsrF6ykI4gTlBxVD7Lu4zWGoZMBEZ+yY/S/54/2eL1FHhxUpfBfwnyPCR4PPNQIvsKGTA/Qa8P/YB2xD7jS/UaE5PMdYQH6G8/fZlQk1+gdECsZkWiG1RMInRH3ACaAuwqYG7MloysAJREEEs2jMB6gcd8vNTr0bUIYtoashSobcCW45T2B5qzHHpgoDQc/aEjFWcP2V7RbE4uvDV4b54qSJSUmQVeC4hzy0qym2mETnvKL+dfUg/pdkVm0FoA3iBiQzbDPPSe9L79xzieJCDmG9JgRu9KTECCWWmlY9DkGF569H8u5DT1eHIb+4H35pnhBYLwIwAAAAASUVORK5CYII=" alt="" /><img src="data:image/png;base64,iVBORw0KGgoAAAANSUhEUgAAABEAAAATCAYAAAB2pebxAAABEElEQVR4nOWUMW6DMBSGfySOgpeqJ4ATBHav2ehoH4CxBwhjsrF6ykI4gTlBxVD7Lu4zWGoZMBEZ+yY/S/54/2eL1FHhxUpfBfwnyPCR4PPNQIvsKGTA/Qa8P/YB2xD7jS/UaE5PMdYQH6G8/fZlQk1+gdECsZkWiG1RMInRH3ACaAuwqYG7MloysAJREEEs2jMB6gcd8vNTr0bUIYtoashSobcCW45T2B5qzHHpgoDQc/aEjFWcP2V7RbE4uvDV4b54qSJSUmQVeC4hzy0qym2mETnvKL+dfUg/pdkVm0FoA3iBiQzbDPPSe9L79xzieJCDmG9JgRu9KTECCWWmlY9DkGF569H8u5DT1eHIb+4H35pnhBYLwIwAAAAASUVORK5CYII=" alt="" /></li>
</ul>
<p><img src="data:image/png;base64,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" alt="" /></p>
<p><img src="data:image/png;base64,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" alt="" /></p>
<p style="text-align: center;"><span style="text-decoration: underline;"><img height="474" width="635" src="/assets/courseware/v1/af87dff3707633ce5fa55bb780178e77/asset-v1:Profosvita+CS-K008SFPL+2024+type@asset+block/%D0%9C%D0%BE%D0%B4%D1%83%D0%BB%D1%8C2_%D0%95%D0%BB%D0%B5%D0%BA%D1%82%D1%80%D0%BE%D0%BE%D0%B1%D0%BB%D0%B0%D0%B4%D0%BD%D0%B0%D0%BD%D0%BD%D1%8F__2._%D0%92%D0%B8%D0%BC%D0%B8%D0%BA%D0%B0%D1%87%D1%96_%D0%BD%D0%B8%D0%B7%D1%8C%D0%BA%D0%BE%D1%97_%D0%BD%D0%B0%D0%BF%D1%80%D1%83%D0%B3%D0%B8_%D1%82%D0%B0_%D0%B4%D0%B6%D0%B5%D1%80%D0%B5%D0%BB%D0%B0_%D1%81%D0%B2%D1%96%D1%82%D0%BB%D0%B0_html_86203c0a1ebe2440.jpg" alt="" /></span></p>
<p style="text-align: center;"><span style="text-decoration: underline;">Рисунок 2.8: Трифазний автоматичний вимикач залишкового струму; (а) ескіз конструкції автоматичного вимикача (б) методу установки; 1- підсумковий трансформатор, 2- реле залишкового струму, 3-ланцюговий вимикач блокування, R d-обмежуючий резистор, PK-кнопка управління</span></p>
<p>Якщо відбувається ослаблення або пошкодження наземної ізоляції в контурі живлення, в результаті чого струм витоку 𝐼 тече в землю або захисний провідник PE, то сума струмів в проводах підсумкового трансформатора перестає дорівнювати нулю. В сердечнику підсумовуючого трансформатора буде створюватися змінний в часі магнітний потік, який в котушці напруги трансформатора залишкового струму індукує напругу значення якої залежить від струму І. Коли цей струм перевищує значення струму відключення, то реле спрацьовує і вимикач відключається. Якщо в контурі живлення є струми витоку, викликані пошкодженням ізоляції або в результаті природних властивостей приймачів зі значеннями, більшими за струм відключення автоматичного вимикача, то включити таку схему або такі пристрої не вдасться – навіть, якщо вони будуть технічно справні. У таких випадках використовуються менш чутливі автоматичні вимикачі залишкового струму. Ці типи вимикачів використовуються для захисту від ураження електричним струмом.</p>
<p style="text-align: center;"><span style="text-decoration: underline;"><img height="476" width="480" src="/assets/courseware/v1/48349946a6afceb2e2db77c0b2dc0826/asset-v1:Profosvita+CS-K008SFPL+2024+type@asset+block/%D0%9C%D0%BE%D0%B4%D1%83%D0%BB%D1%8C2_%D0%95%D0%BB%D0%B5%D0%BA%D1%82%D1%80%D0%BE%D0%BE%D0%B1%D0%BB%D0%B0%D0%B4%D0%BD%D0%B0%D0%BD%D0%BD%D1%8F__2._%D0%92%D0%B8%D0%BC%D0%B8%D0%BA%D0%B0%D1%87%D1%96_%D0%BD%D0%B8%D0%B7%D1%8C%D0%BA%D0%BE%D1%97_%D0%BD%D0%B0%D0%BF%D1%80%D1%83%D0%B3%D0%B8_%D1%82%D0%B0_%D0%B4%D0%B6%D0%B5%D1%80%D0%B5%D0%BB%D0%B0_%D1%81%D0%B2%D1%96%D1%82%D0%BB%D0%B0_html_12e002042d859568.jpg" alt="" /></span></p>
<p style="text-align: center;"><span style="text-decoration: underline;">Рисунок 2.9 Автоматичний вимикач залишкового струму</span></p>
<p><em>Джерело: http://www.tme.eu/pl/katalog/</em></p>
<ul>
<li><em>програмовані часові перемикачі</em> дозволяють автоматично вмикати і вимикати схеми і приймачі за заявленою програмою з хвилинною точністю і на кілька днів вперед, найчастіше для кожного дня тижня. Комутаційна потужність контактів становить 10-16 А і напруга 240 В. При більших значеннях робочих струмів приймачів використовуються додаткові контактори</li>
</ul>
<p style="text-align: center;"><span style="text-decoration: underline;"><img height="200" width="700" src="/assets/courseware/v1/7c798309e11a571b7735b4419d56964f/asset-v1:Profosvita+CS-K008SFPL+2024+type@asset+block/%D0%9C%D0%BE%D0%B4%D1%83%D0%BB%D1%8C2_%D0%95%D0%BB%D0%B5%D0%BA%D1%82%D1%80%D0%BE%D0%BE%D0%B1%D0%BB%D0%B0%D0%B4%D0%BD%D0%B0%D0%BD%D0%BD%D1%8F__2._%D0%92%D0%B8%D0%BC%D0%B8%D0%BA%D0%B0%D1%87%D1%96_%D0%BD%D0%B8%D0%B7%D1%8C%D0%BA%D0%BE%D1%97_%D0%BD%D0%B0%D0%BF%D1%80%D1%83%D0%B3%D0%B8_%D1%82%D0%B0_%D0%B4%D0%B6%D0%B5%D1%80%D0%B5%D0%BB%D0%B0_%D1%81%D0%B2%D1%96%D1%82%D0%BB%D0%B0_html_bf7e004e080dca2c.jpg" alt="" /></span></p>
<p style="text-align: center;"><span style="text-decoration: underline;">Рисунок 2.10 Програмовані часові перемикачі</span></p>
<p><em>Джерело: http://elektrosystemy.pl/</em></p>
<ul>
<li>сутінкові вимикачі призначені для автоматичного включення і виключення схем освітлення, коли фотоелемент, що вимірює освітленість, визначає перевищення встановлених граничних значень. Відключення ланцюгів може відбуватися з певною затримкою часу. Граничні значення освітленості коливаються від 1 до 200 люкс</li>
</ul>
<p style="text-align: center;"><img height="222" width="500" src="/assets/courseware/v1/d5a5b43bbc1ddd447803265367d2ea42/asset-v1:Profosvita+CS-K008SFPL+2024+type@asset+block/%D0%9C%D0%BE%D0%B4%D1%83%D0%BB%D1%8C2_%D0%95%D0%BB%D0%B5%D0%BA%D1%82%D1%80%D0%BE%D0%BE%D0%B1%D0%BB%D0%B0%D0%B4%D0%BD%D0%B0%D0%BD%D0%BD%D1%8F__2._%D0%92%D0%B8%D0%BC%D0%B8%D0%BA%D0%B0%D1%87%D1%96_%D0%BD%D0%B8%D0%B7%D1%8C%D0%BA%D0%BE%D1%97_%D0%BD%D0%B0%D0%BF%D1%80%D1%83%D0%B3%D0%B8_%D1%82%D0%B0_%D0%B4%D0%B6%D0%B5%D1%80%D0%B5%D0%BB%D0%B0_%D1%81%D0%B2%D1%96%D1%82%D0%BB%D0%B0_html_ea378492def36b62.jpg" alt="" /></p>
<p style="text-align: center;"><span style="text-decoration: underline;">Рисунок 2.11 Сутінкові перемикачі Finder</span></p>
<p><em>Джерело: http://www.tme.eu/</em></p>
<ul>
<li><em>Програмовані терморегулятори</em> використовуються для контролю і регулювання температури в різний час доби і в різні дні тижня. Вони призначені для використання в житлових приміщеннях і будь-яких інших громадських будівлях, з діапазоном регулювання температури від 5 до 30 градусів за Цельсієм. Існують також промислові терморегулятори для холодильних або саунних застосувань в діапазоні регулювання від -30 до 90 ° C</li>
</ul>
<p style="text-align: center;"><img height="357" width="500" src="/assets/courseware/v1/74025732fd996b8857878618fb5a0939/asset-v1:Profosvita+CS-K008SFPL+2024+type@asset+block/%D0%9C%D0%BE%D0%B4%D1%83%D0%BB%D1%8C2_%D0%95%D0%BB%D0%B5%D0%BA%D1%82%D1%80%D0%BE%D0%BE%D0%B1%D0%BB%D0%B0%D0%B4%D0%BD%D0%B0%D0%BD%D0%BD%D1%8F__2._%D0%92%D0%B8%D0%BC%D0%B8%D0%BA%D0%B0%D1%87%D1%96_%D0%BD%D0%B8%D0%B7%D1%8C%D0%BA%D0%BE%D1%97_%D0%BD%D0%B0%D0%BF%D1%80%D1%83%D0%B3%D0%B8_%D1%82%D0%B0_%D0%B4%D0%B6%D0%B5%D1%80%D0%B5%D0%BB%D0%B0_%D1%81%D0%B2%D1%96%D1%82%D0%BB%D0%B0_html_2f1d03d05a58f02c.jpg" alt="" /></p>
<p style="text-align: center;"><span style="text-decoration: underline;">Рисунок 2.12 Програмований терморегулятор із зовнішнім зондом</span></p>
<p>Джерело: http://www.deltadore.com/</p>
<ul>
<li><em>пріоритетні реле</em> призначені для використання в установках, де може бути періодичне включення надмірної кількості приймачів, що викликають перевантаження установки і експлуатації пристроїв безпеки. Щоб уникнути відключення великих частин установки, встановлюються такі реле, де також може бути проведена поділ на пріоритетні і вторинні контури;</li>
</ul>
<p style="text-align: center;"><img height="330" width="330" src="/assets/courseware/v1/542ecff9b337ebbacb446207f3ed7c53/asset-v1:Profosvita+CS-K008SFPL+2024+type@asset+block/%D0%9C%D0%BE%D0%B4%D1%83%D0%BB%D1%8C2_%D0%95%D0%BB%D0%B5%D0%BA%D1%82%D1%80%D0%BE%D0%BE%D0%B1%D0%BB%D0%B0%D0%B4%D0%BD%D0%B0%D0%BD%D0%BD%D1%8F__2._%D0%92%D0%B8%D0%BC%D0%B8%D0%BA%D0%B0%D1%87%D1%96_%D0%BD%D0%B8%D0%B7%D1%8C%D0%BA%D0%BE%D1%97_%D0%BD%D0%B0%D0%BF%D1%80%D1%83%D0%B3%D0%B8_%D1%82%D0%B0_%D0%B4%D0%B6%D0%B5%D1%80%D0%B5%D0%BB%D0%B0_%D1%81%D0%B2%D1%96%D1%82%D0%BB%D0%B0_html_672675d10288d361.jpg" alt="" /></p>
<p style="text-align: center;"><span style="text-decoration: underline;">Рисунок 2.13 Пріоритетне реле</span></p>
<p><em>Джерело: http://www.ihe24.pl/przekazniki-priorytetowe/</em></p>
<ul>
<li><em>багатофункціональні роз'єми</em> характеризуються різними можливостями комутації. Вони використовуються для освітлення сходів та інших приміщень, надаючи різні варіанти перемикання.</li>
</ul>
<p style="text-align: center;"><span style="text-decoration: underline;"><img height="295" width="304" src="/assets/courseware/v1/ab9eb9ff6713673240dbde4966dbd4f3/asset-v1:Profosvita+CS-K008SFPL+2024+type@asset+block/%D0%9C%D0%BE%D0%B4%D1%83%D0%BB%D1%8C2_%D0%95%D0%BB%D0%B5%D0%BA%D1%82%D1%80%D0%BE%D0%BE%D0%B1%D0%BB%D0%B0%D0%B4%D0%BD%D0%B0%D0%BD%D0%BD%D1%8F__2._%D0%92%D0%B8%D0%BC%D0%B8%D0%BA%D0%B0%D1%87%D1%96_%D0%BD%D0%B8%D0%B7%D1%8C%D0%BA%D0%BE%D1%97_%D0%BD%D0%B0%D0%BF%D1%80%D1%83%D0%B3%D0%B8_%D1%82%D0%B0_%D0%B4%D0%B6%D0%B5%D1%80%D0%B5%D0%BB%D0%B0_%D1%81%D0%B2%D1%96%D1%82%D0%BB%D0%B0_html_5be54abe7f09f00.jpg" alt="" /></span></p>
<p style="text-align: center;"><span style="text-decoration: underline;">Рисунок 2.14 FINDER багатофункціональний роз'єм</span></p>
<p><em>Джерело: http://www.findernet.com/</em></p>
<div id="gtx-trans" style="position: absolute; left: -37px; top: 3043.53px;">
<div class="gtx-trans-icon"></div>
</div>
</div>
</div>
</div>
<script type="text/javascript">
(function (require) {
require(['/static/js/dateutil_factory.762fd6ff462b.js?raw'], function () {
require(['js/dateutil_factory'], function (DateUtilFactory) {
DateUtilFactory.transform('.localized-datetime');
});
});
}).call(this, require || RequireJS.require);
</script>
<script>
function emit_event(message) {
parent.postMessage(message, '*');
}
</script>
</div>
Завершення тесту
У вас залишилися невиконані завдання. Ви впевнені, що хочете завершити тест?
Тестування завершено.
Щоб переглянути результат
перейдіть на сторінку "Прогрес"