<div class="xblock xblock-public_view xblock-public_view-vertical" data-course-id="course-v1:Profosvita+CS-M213+2023" data-init="VerticalStudentView" data-runtime-class="LmsRuntime" data-runtime-version="1" data-block-type="vertical" data-usage-id="block-v1:Profosvita+CS-M213+2023+type@vertical+block@1c34e6dca57d4aeca09b7d3de114f1a5" data-request-token="344ee538224111f09d7d6e64c045cccd" data-graded="False" data-has-score="False">
<div class="vert-mod">
<div class="vert vert-0" data-id="block-v1:Profosvita+CS-M213+2023+type@html+block@aa2d2261456241deaf1aa766a82a533f">
<div class="xblock xblock-public_view xblock-public_view-html xmodule_display xmodule_HtmlBlock" data-course-id="course-v1:Profosvita+CS-M213+2023" data-init="XBlockToXModuleShim" data-runtime-class="LmsRuntime" data-runtime-version="1" data-block-type="html" data-usage-id="block-v1:Profosvita+CS-M213+2023+type@html+block@aa2d2261456241deaf1aa766a82a533f" data-request-token="344ee538224111f09d7d6e64c045cccd" data-graded="False" data-has-score="False">
<script type="json/xblock-args" class="xblock-json-init-args">
{"xmodule-type": "HTMLModule"}
</script>
<p style="text-align: justify;">Електропроводки, що прокладаються по зовнішніх стінах будинків і споруд, а також між будинками на опорах (не більше чотирьох прольотів по 25 м кожний), називаються <strong><em>зовнішніми</em></strong>. Ці електропроводки можуть виконуватися проводами й кабелями і можуть бути відкриті та сховані.</p>
<p style="text-align: center;"><img width="600" src="/assets/courseware/v1/9eee43c44eaf0690865a8abd738c55b0/asset-v1:Profosvita+CS-M213+2023+type@asset+block/t9i1.jpg" alt="" /></p>
<p style="text-align: justify;"><strong>Зовнішня проводка</strong> - це спосіб кріплення проводів, кабелів і відповідних аксесуарів на поверхні стін, підлоги і стелі. Вона дозволяє без зусиль швидко знайти джерело несправності та усунути його, замінити при необхідності ділянку проводу або зробити розводку для монтажу нової розетки або вимикача. Крім очевидної зручності експлуатації зовнішня електрична проводка виконує декоративну функцію. </p>
<p style="text-align: center;"><img width="600" src="/assets/courseware/v1/d9d72626085bda168d17007c6974eec1/asset-v1:Profosvita+CS-M213+2023+type@asset+block/t9i2.jpg" alt="" /></p>
<p style="text-align: justify;">До зовнішніх електропроводок належать також і вводи в будинки та споруди від повітряних ліній електропередач, що з'єднують розгалуження від цих ліній до внутрішньої електропроводки, починаючи від ізоляторів, встановлених на зовнішній поверхні стіни чи даху будинку, до затискачів ввідного пристрою.</p>
<p style="text-align: justify;">При прокладанні зовнішньої електропроводки незахищеними ізольованими проводами, їх розміщують так, щоб вони були недоступні, на безпечній відстані для людей.</p>
<p style="text-align: justify;">При горизонтальному прокладанні під покрівлею, балконом чи терасою ця відстань повинна бути не меншою ніж 2,5 м, над вікнами — 0,5 м, під вікнами і балконом — 1 м. При вертикальному прокладанні — не менше 0,75 м до вікна і 1 м до балкона. Проводи прокладають від землі на відстані не меншій 2,75 м.</p>
<p style="text-align: justify;">Якщо проводи підвішують на опорах, біля будинків, то відстань до балконів і вікон повинна бути не меншою 1,5 м при невеликому їх відхиленні. Якщо прольоти між опорами становлять до 6 м, то відстань між проводами повинна бути не меншою 0,1 м, при прольоті більше 6 м — не менше 0,15 м. В усіх випадках відстань від проводів до стін і опорних конструкцій не повинна бути меншою 50 мм.</p>
<p style="text-align: justify;">Під покрівлями житлових, громадських будинків і глядацьких споруд не можна прокладати зовнішню електропроводку (винятком є вводи у будинки і розгалуження до них). </p>
<p style="text-align: justify;">Вводи у будинки прокладають через стіни в ізоляційних трубках. Допускається виконувати ці вводи через покрівлі у стальних трубах, в торгових павільйонах, кіосках, пересувних будках й інших спорудах невеликої висоти, на покрівлях яких виключене перебування людей. При цьому відстань від проводів до покрівлі повинна бути не меншою 0,5 м. </p>
<p style="text-align: justify;">Зовнішня електропроводка по покрівлях житлових, громадських будинків та глядацьких споруд <strong>НЕ ДОПУСТИМА</strong>.</p>
<p style="text-align: justify;">Електропроводка відкритого типу може прокладатися по опорах, стелі, площі стін та інших конструктивних частин будівель. Прокладка здійснюється кількома способами: у металевих або поліетиленових трубах, по площі стін та будівельних конструкцій, на перекриттях по тросах, струнах, роликах, в коробках та на спеціальних лотках.</p>
<p style="text-align: center;"><img width="660" src="/assets/courseware/v1/dd299649725746a8cab98a2a8f142a9e/asset-v1:Profosvita+CS-M213+2023+type@asset+block/t9i3.jpg" alt="" /></p>
<p style="text-align: justify;">Струнна електропроводка використовуються для оснащення розподільних, магістральних ліній в силових мережах та освітленні з зовнішньої і внутрішньої сторони приміщень. Кабелі у струнних електропроводках підвішуються на сталевій струні, впритул приєднуваній до виступів різних будівельних елементів.</p>
<p></p>
</div>
</div>
</div>
<script type="text/javascript">
(function (require) {
require(['/static/js/dateutil_factory.762fd6ff462b.js?raw'], function () {
require(['js/dateutil_factory'], function (DateUtilFactory) {
DateUtilFactory.transform('.localized-datetime');
});
});
}).call(this, require || RequireJS.require);
</script>
<script>
function emit_event(message) {
parent.postMessage(message, '*');
}
</script>
</div>
<div class="xblock xblock-public_view xblock-public_view-vertical" data-course-id="course-v1:Profosvita+CS-M213+2023" data-init="VerticalStudentView" data-runtime-class="LmsRuntime" data-runtime-version="1" data-block-type="vertical" data-usage-id="block-v1:Profosvita+CS-M213+2023+type@vertical+block@e0a37eb00f36424c841c99c75c779bf6" data-request-token="344ee538224111f09d7d6e64c045cccd" data-graded="False" data-has-score="False">
<div class="vert-mod">
<div class="vert vert-0" data-id="block-v1:Profosvita+CS-M213+2023+type@html+block@963a0cbf5d654d84ae007c79fc5abc6d">
<div class="xblock xblock-public_view xblock-public_view-html xmodule_display xmodule_HtmlBlock" data-course-id="course-v1:Profosvita+CS-M213+2023" data-init="XBlockToXModuleShim" data-runtime-class="LmsRuntime" data-runtime-version="1" data-block-type="html" data-usage-id="block-v1:Profosvita+CS-M213+2023+type@html+block@963a0cbf5d654d84ae007c79fc5abc6d" data-request-token="344ee538224111f09d7d6e64c045cccd" data-graded="False" data-has-score="False">
<script type="json/xblock-args" class="xblock-json-init-args">
{"xmodule-type": "HTMLModule"}
</script>
<p style="text-align: justify;">Завести електричний кабель в будинок можна двома способами: повітряним і підземним. </p>
<p style="text-align: justify;">За правилами підключення до <em><strong>ліній електропередач</strong></em> (ЛЕП):</p>
<ul style="text-align: justify;">
<ul>
<li>відстань від стовпа до повітряного вводу в будинок не повинно перевищувати 10 м;</li>
<li>якщо ЛЕП знаходиться на відстані більше 10 м, необхідно встановити додаткову опору, відстань від ЛЕП до проміжної опори не повинна перевищувати 15 м;</li>
<li>відгалуження для прольоту до 10 м потрібно робити мідними проводами 4 мм, від 10 до 25 м - мідними проводами 6 мм.</li>
</ul>
</ul>
<p style="text-align: justify;"><strong>1. Повітряний спосіб</strong></p>
<p style="text-align: justify;">Для повітряного вводу в приватні будинки використовується ізольований алюмінієвий провід марки СІП, його ізоляція стійка до перепадів температури і впливу сонця та опадів. СІП немає необхідності кріпити до тросу. Для повітряного вводу використовується 2- (220 В) або 4- (380 В) жильні дроти перерізом 16 мм². </p>
<p style="text-align: justify;">Перекидається провід (марка СІП, переріз 16 мм²) від лінії електропередачі до будинку. Біля входу в будинок провід СІП за допомогою клем приєднується до проводу марки ВВГ або NYM (переріз 10 мм²). </p>
<p style="text-align: center;"><img width="600" src="/assets/courseware/v1/ea9af409a2698605723ab17f8f999962/asset-v1:Profosvita+CS-M213+2023+type@asset+block/t9i4.jpg" alt="" /></p>
<p style="text-align: justify;">Далі кабель проводимо через прохід в даху або стіні в металевій трубі і введемо електричний кабель до електрощита в будинку. </p>
<p style="text-align: center;"><img width="469" src="/assets/courseware/v1/08fedd1f1f221d59825edf3ed1a66f6d/asset-v1:Profosvita+CS-M213+2023+type@asset+block/t9i5.jpg" alt="" /></p>
<p style="text-align: justify;">Іноді для введення кабелю в будинок використовується трубостійка з натяжкою. Дроти доходять до ізоляторів, закріплених на трубостійки і потім до них підключається кабель або провід, який через вигнуту трубу стійки і наскрізну через стіну трубу заходять усередину будинку. Всі металеві конструкції введення повинні бути заземлені.</p>
<p style="text-align: center;"><img width="700" src="/assets/courseware/v1/e16b3d1dd28455abf8e5d0abe0789d97/asset-v1:Profosvita+CS-M213+2023+type@asset+block/t9i6.jpg" alt="" /></p>
<p style="text-align: justify;">Протягування кабелю крізь дерев'яні стіни можливо, лише зробивши гільзовку, тобто вставивши в деревину металеву трубку і закривши порожній простір базальтовою ватою, яка не горить. </p>
<p style="text-align: center;"><img width="700" src="/assets/courseware/v1/ac341d9fdbbc8488289ceac318abb38d/asset-v1:Profosvita+CS-M213+2023+type@asset+block/t9i7.jpg" alt="" /></p>
<p style="text-align: justify;">При повітряному вводі неізольований кабель протягують через стіну на висоті 2,75 м. Якщо це СІП, його протягують на висоті 2,5 м.</p>
<p style="text-align: justify;"><strong>2. Підземний спосіб</strong></p>
<p style="text-align: justify;">Для підземного електричного вводу кабелю копається траншея від опори ПЛ до будинку глибиною 80–100 см. Спуск кабелю з опори в землю здійснюється в трубі, висота якої від рівня ґрунту повинна бути не менше 2 метрів.</p>
<p style="text-align: justify;">Кабель можна використовувати будь перерізом не менше 16 мм². Але при використанні марки ВВГ, АВВГ і т. п. кабель необхідно прокладати в металевих або пластикових трубах, але якщо застосувати броньований ВбБШв - труби використовуються тільки в місцях спуску або підйому вище ґрунту. </p>
<p style="text-align: justify;"></p>
<div style="border: 2px solid #f95f5f; padding: 20px; box-shadow: #c3cad3 0px 0px 10px; text-align: justify;">
<p style="color: #f95f5f;"><strong>УВАГА!</strong></p>
<p>Струмопровідна оболонка броньованого кабелю повинна бути заземлена з двох сторін: на ПЛ і в електрощиті будинку.</p>
</div>
<p></p>
<p style="text-align: center;"><img width="600" src="/assets/courseware/v1/2c9f29c9afb08b5cbf5d0f13d4834800/asset-v1:Profosvita+CS-M213+2023+type@asset+block/t9i8.jpg" alt="" /></p>
<p style="text-align: justify;">Спершу кабель спускають до землі по стовпу ЛЕП. Нижню ділянку кабелю (приблизно 1,5 м) одягають в металеву трубу - робиться це для того, щоб техніка і люди, які орудують різними інструментами, не могли його пошкодити. Від стовпа ЛЕП до будинку риють траншею. Глибина її повинна становити 0,8-1 м. Дно траншеї засипається піском, шаром близько 10 см. Якщо рельєф місцевості такий, що будинок вище підстави опори ЛЕП і траншея прорита з ухилом від будівлі до опори, підземні води будуть легко відводитися. Якщо ж рівень однаковий або будинок в низині, пісок послужить дренажем. </p>
<p style="text-align: center;"><img width="600" src="/assets/courseware/v1/cb39dae8407c32a897e3fb4e0dc2da7d/asset-v1:Profosvita+CS-M213+2023+type@asset+block/t9i9.png" alt="" /></p>
<p style="text-align: justify;">Після прокладки кабелю знову засипають 10 см піску, потім ґрунт. При засипці треба стежити, щоб камені не потрапили на кабель - осідаючи, вони можуть його пошкодити. Щоб згодом не зачепити кабель, прокладають поверх другого шару піску сигнальну стрічку. Таку ж стрічку прокладають, якщо стовп ЛЕП стоїть на протилежному боці вулиці і траншея проходить під вулицею. Через фундамент протягуємо кабель в будинок, а якщо фундаменту немає, піднімаємо його в трубі по стіні на висоту 1,8 м, після чого вводимо в будинок.</p>
<p></p>
<p></p>
</div>
</div>
</div>
<script type="text/javascript">
(function (require) {
require(['/static/js/dateutil_factory.762fd6ff462b.js?raw'], function () {
require(['js/dateutil_factory'], function (DateUtilFactory) {
DateUtilFactory.transform('.localized-datetime');
});
});
}).call(this, require || RequireJS.require);
</script>
<script>
function emit_event(message) {
parent.postMessage(message, '*');
}
</script>
</div>
<div class="xblock xblock-public_view xblock-public_view-vertical" data-course-id="course-v1:Profosvita+CS-M213+2023" data-init="VerticalStudentView" data-runtime-class="LmsRuntime" data-runtime-version="1" data-block-type="vertical" data-usage-id="block-v1:Profosvita+CS-M213+2023+type@vertical+block@cde4c8656ca1481382002b7d9b414c49" data-request-token="344ee538224111f09d7d6e64c045cccd" data-graded="False" data-has-score="False">
<div class="vert-mod">
<div class="vert vert-0" data-id="block-v1:Profosvita+CS-M213+2023+type@problem+block@a88b6569269448e48a8068474fe78d33">
<div class="xblock xblock-public_view xblock-public_view-problem xmodule_display xmodule_ProblemBlock" data-course-id="course-v1:Profosvita+CS-M213+2023" data-block-type="problem" data-usage-id="block-v1:Profosvita+CS-M213+2023+type@problem+block@a88b6569269448e48a8068474fe78d33" data-request-token="344ee538224111f09d7d6e64c045cccd" data-graded="False" data-has-score="True">
<div class="page-banner"><div class="alert alert-warning"><span class="icon icon-alert fa fa fa-warning" aria-hidden="true"></span><div class="message-content">Питання 1 доступне для перегляду та виконання після <a href=/register>реєстрації</a>/<a href=/login>авторизації</a> на платформі.</div></div></div>
</div>
</div>
<div class="vert vert-1" data-id="block-v1:Profosvita+CS-M213+2023+type@problem+block@f3b648250a0546b68edf6069d29284d1">
<div class="xblock xblock-public_view xblock-public_view-problem xmodule_display xmodule_ProblemBlock" data-course-id="course-v1:Profosvita+CS-M213+2023" data-block-type="problem" data-usage-id="block-v1:Profosvita+CS-M213+2023+type@problem+block@f3b648250a0546b68edf6069d29284d1" data-request-token="344ee538224111f09d7d6e64c045cccd" data-graded="False" data-has-score="True">
<div class="page-banner"><div class="alert alert-warning"><span class="icon icon-alert fa fa fa-warning" aria-hidden="true"></span><div class="message-content">Питання 2 доступне для перегляду та виконання після <a href=/register>реєстрації</a>/<a href=/login>авторизації</a> на платформі.</div></div></div>
</div>
</div>
<div class="vert vert-2" data-id="block-v1:Profosvita+CS-M213+2023+type@problem+block@f4c3ee13bb784d28931758be45ed28ec">
<div class="xblock xblock-public_view xblock-public_view-problem xmodule_display xmodule_ProblemBlock" data-course-id="course-v1:Profosvita+CS-M213+2023" data-block-type="problem" data-usage-id="block-v1:Profosvita+CS-M213+2023+type@problem+block@f4c3ee13bb784d28931758be45ed28ec" data-request-token="344ee538224111f09d7d6e64c045cccd" data-graded="False" data-has-score="True">
<div class="page-banner"><div class="alert alert-warning"><span class="icon icon-alert fa fa fa-warning" aria-hidden="true"></span><div class="message-content">Питання 3 доступне для перегляду та виконання після <a href=/register>реєстрації</a>/<a href=/login>авторизації</a> на платформі.</div></div></div>
</div>
</div>
<div class="vert vert-3" data-id="block-v1:Profosvita+CS-M213+2023+type@problem+block@635a26d035a24ae5b11828bd39341ff3">
<div class="xblock xblock-public_view xblock-public_view-problem xmodule_display xmodule_ProblemBlock" data-course-id="course-v1:Profosvita+CS-M213+2023" data-block-type="problem" data-usage-id="block-v1:Profosvita+CS-M213+2023+type@problem+block@635a26d035a24ae5b11828bd39341ff3" data-request-token="344ee538224111f09d7d6e64c045cccd" data-graded="False" data-has-score="True">
<div class="page-banner"><div class="alert alert-warning"><span class="icon icon-alert fa fa fa-warning" aria-hidden="true"></span><div class="message-content">Питання 4 доступне для перегляду та виконання після <a href=/register>реєстрації</a>/<a href=/login>авторизації</a> на платформі.</div></div></div>
</div>
</div>
<div class="vert vert-4" data-id="block-v1:Profosvita+CS-M213+2023+type@problem+block@2a2024c073a94ee789271bbba56e81a7">
<div class="xblock xblock-public_view xblock-public_view-problem xmodule_display xmodule_ProblemBlock" data-course-id="course-v1:Profosvita+CS-M213+2023" data-block-type="problem" data-usage-id="block-v1:Profosvita+CS-M213+2023+type@problem+block@2a2024c073a94ee789271bbba56e81a7" data-request-token="344ee538224111f09d7d6e64c045cccd" data-graded="False" data-has-score="True">
<div class="page-banner"><div class="alert alert-warning"><span class="icon icon-alert fa fa fa-warning" aria-hidden="true"></span><div class="message-content">Питання 5 доступне для перегляду та виконання після <a href=/register>реєстрації</a>/<a href=/login>авторизації</a> на платформі.</div></div></div>
</div>
</div>
<div class="vert vert-5" data-id="block-v1:Profosvita+CS-M213+2023+type@problem+block@ffb695397258434fb7929bbb4ad8807f">
<div class="xblock xblock-public_view xblock-public_view-problem xmodule_display xmodule_ProblemBlock" data-course-id="course-v1:Profosvita+CS-M213+2023" data-block-type="problem" data-usage-id="block-v1:Profosvita+CS-M213+2023+type@problem+block@ffb695397258434fb7929bbb4ad8807f" data-request-token="344ee538224111f09d7d6e64c045cccd" data-graded="False" data-has-score="True">
<div class="page-banner"><div class="alert alert-warning"><span class="icon icon-alert fa fa fa-warning" aria-hidden="true"></span><div class="message-content">Питання 6 доступне для перегляду та виконання після <a href=/register>реєстрації</a>/<a href=/login>авторизації</a> на платформі.</div></div></div>
</div>
</div>
</div>
<script type="text/javascript">
(function (require) {
require(['/static/js/dateutil_factory.762fd6ff462b.js?raw'], function () {
require(['js/dateutil_factory'], function (DateUtilFactory) {
DateUtilFactory.transform('.localized-datetime');
});
});
}).call(this, require || RequireJS.require);
</script>
<script>
function emit_event(message) {
parent.postMessage(message, '*');
}
</script>
</div>
<div class="xblock xblock-public_view xblock-public_view-vertical" data-course-id="course-v1:Profosvita+CS-M213+2023" data-init="VerticalStudentView" data-runtime-class="LmsRuntime" data-runtime-version="1" data-block-type="vertical" data-usage-id="block-v1:Profosvita+CS-M213+2023+type@vertical+block@ed1177fb26ce4c08b5e603e1aee5eeb5" data-request-token="344ee538224111f09d7d6e64c045cccd" data-graded="False" data-has-score="False">
<div class="vert-mod">
<div class="vert vert-0" data-id="block-v1:Profosvita+CS-M213+2023+type@html+block@01eb0bf1ef5444f68e9e531acbe30657">
<div class="xblock xblock-public_view xblock-public_view-html xmodule_display xmodule_HtmlBlock" data-course-id="course-v1:Profosvita+CS-M213+2023" data-init="XBlockToXModuleShim" data-runtime-class="LmsRuntime" data-runtime-version="1" data-block-type="html" data-usage-id="block-v1:Profosvita+CS-M213+2023+type@html+block@01eb0bf1ef5444f68e9e531acbe30657" data-request-token="344ee538224111f09d7d6e64c045cccd" data-graded="False" data-has-score="False">
<script type="json/xblock-args" class="xblock-json-init-args">
{"xmodule-type": "HTMLModule"}
</script>
<p style="text-align: justify;">Тимчасові електропроводки монтують зовні або всередині будинків, на будівельних майданчиках, для святкових ілюмінацій і тривалістю не більше, як на пів року.</p>
<p style="text-align: justify;">Залежно від розташування ділянки, на якому відбувається будівництво, здійснюється вибір способу для підведення тимчасового електропостачання. На вибір виду прокладки кабелю впливають такі моменти:</p>
<ul style="text-align: justify;">
<ul>
<li>Відстань від лінії електропередач.</li>
<li>Вид об'єкту: житловий будинок, складські приміщення або виробничий цех.</li>
<li>Розрахункова потужність споживання.</li>
<li>Вибір мережі: однофазна або трифазна.</li>
<li>Стан найближчій повітряної лінії електропередач.</li>
</ul>
</ul>
<p style="text-align: justify;">Виходячи з цих потреб електроенергії вибирається найкращий спосіб монтажу тимчасового електропостачання на будівельному майданчику. Це може бути підключення до існуючих мереж або установка автономного електрогенератора.</p>
<p style="text-align: justify;"><strong>Вимоги до тимчасового електропостачання ділянки, на якому виробляють будівельні роботи:</strong></p>
<ul>
<ul>
<li style="text-align: justify;">Надійність. Безперебійне постачання електрикою на період будівництва. </li>
<li style="text-align: justify;">Якість. Частота і напруга повинні гарантувати роботу електричних пристроїв.</li>
<li style="text-align: justify;">Безпека. Максимальний захист персоналу та операторів на будівельного майданчику.</li>
</ul>
</ul>
<p style="text-align: justify;"><strong>Підключення тимчасового електропостачання:</strong></p>
<p style="text-align: justify;">1) <em>Будівництво проводиться в безпосередній близькості існуючої електромережі</em>. </p>
<p style="text-align: justify;">Живлення береться від власного житла або від сусідів (за згодою та дозволом).</p>
<p style="text-align: justify;">2) <em>Будівництво нової повітряної лінії</em>.</p>
<p style="text-align: justify;">Будівельний майданчик знаходить далеко від ліній електропередач, тоді будують нову повітряну лінію (ПЛ).</p>
<p style="text-align: justify;">3) <em>Постачання електрики від електрогенератора</em>. </p>
<p style="text-align: justify;">З технічної точки зору генераторні установки забезпечують якісну електроенергію. Будівельники використовують їх на свій розсуд і ні від кого не залежать. Недолік - це висока вартість виробленої електроенергії. </p>
<p style="text-align: justify;">Для забезпечення тимчасового живлення будівельного майданчика встановлюють щиток зовнішнього антивандального виконання з класом захисту IP54. Габарити щитка повинні бути такими, щоб була можливість установки лічильника і апаратів захисту, розеток і шин заземлення. Також потрібно передбачити місце для резервного електропостачання.</p>
<p style="text-align: justify;"><strong>Технічні заходи тимчасового електропостачання.</strong> </p>
<p style="text-align: justify;">Після вирішення всіх організаційних питань і вибору схеми тимчасового електропостачання на будівельному майданчику визначають місце для установки щита введення на стійці або опорі. </p>
<p style="text-align: justify;">Встановлюють додаткову опору в разі віддалення ділянки від лінії електропередач більш ніж на 25 метрів. Але це значення може відрізнятися і в меншу сторону відповідно до ПУЕ глави 2.4. п. 2.4.19. За правилами щит введення встановлюється на кордоні або території заявника. </p>
<p style="text-align: justify;">Від вступного ящика вже проводиться розмітка кабельних трас або опор електропередач до місця проведення робіт, силових і освітлювальних мереж. Для оптимального розподілу потужності по будівельній ділянці силові дроти підводять до підйомних механізмів, до ділянки приготування бетону, ділянці деревообробки, місця твору зварних робіт.</p>
<p style="text-align: justify;">На початку будівництва система тимчасового освітлення може складатися з декількох прожекторів, і розділяться на основне і аварійне, місцеве або загальне.</p>
<p style="text-align: justify;"><strong>Демонтаж тимчасових електропроводок.</strong></p>
<p style="text-align: justify;">Демонтаж виконується просто, так як вся електропроводка зовнішня та в доступних місцях. Відключаємо живлення з щита, розключаємо його. Складаємо всю кабельну продукцію, яка у нас була розташована по трасах електропроводки.</p>
<p style="text-align: justify;"><strong>Заходи безпеки при тимчасовому електропостачанні.</strong> </p>
<p style="text-align: justify;">Будівництво - це завжди рух і переміщення, в результаті чого можуть виникнути непередбачені ризики. Тому пред'являються особливі вимоги до тимчасового електропостачання, оскільки присутній такий фактор, як несприятливий вплив атмосфери на елементи електроустановок та їх частини. </p>
<p style="text-align: justify;">При роботі в умовах підвищеної вологості потрібно дотримуватися чинних правил ПУЕ 1.7.50-53, які вказують виконувати захист установкою УЗО, у разі непрямого дотику в випадках, якщо напруга перевищує 50 Вольт змінного струму і 120 постійного. Для підвищення безпеки персоналу, які працюють з електроінструментом, потрібно використовувати розділові трансформатори з системою зрівнювання потенціалів, що об'єднує всі відкриті корпуси за допомогою захисних роз’ємів в розетці.</p>
<p style="text-align: justify;">При висвітленні об'єкта, світильники вибирають з класом захистом IP54, для установки на відкритому повітрі. </p>
</div>
</div>
</div>
<script type="text/javascript">
(function (require) {
require(['/static/js/dateutil_factory.762fd6ff462b.js?raw'], function () {
require(['js/dateutil_factory'], function (DateUtilFactory) {
DateUtilFactory.transform('.localized-datetime');
});
});
}).call(this, require || RequireJS.require);
</script>
<script>
function emit_event(message) {
parent.postMessage(message, '*');
}
</script>
</div>
<div class="xblock xblock-public_view xblock-public_view-vertical" data-course-id="course-v1:Profosvita+CS-M213+2023" data-init="VerticalStudentView" data-runtime-class="LmsRuntime" data-runtime-version="1" data-block-type="vertical" data-usage-id="block-v1:Profosvita+CS-M213+2023+type@vertical+block@fe287f18bb3242439fa353023b6eea77" data-request-token="344ee538224111f09d7d6e64c045cccd" data-graded="False" data-has-score="False">
<div class="vert-mod">
<div class="vert vert-0" data-id="block-v1:Profosvita+CS-M213+2023+type@problem+block@0b9d7dfdede546cba9b84ac6ad9d3365">
<div class="xblock xblock-public_view xblock-public_view-problem xmodule_display xmodule_ProblemBlock" data-course-id="course-v1:Profosvita+CS-M213+2023" data-block-type="problem" data-usage-id="block-v1:Profosvita+CS-M213+2023+type@problem+block@0b9d7dfdede546cba9b84ac6ad9d3365" data-request-token="344ee538224111f09d7d6e64c045cccd" data-graded="False" data-has-score="True">
<div class="page-banner"><div class="alert alert-warning"><span class="icon icon-alert fa fa fa-warning" aria-hidden="true"></span><div class="message-content">Питання 1 доступне для перегляду та виконання після <a href=/register>реєстрації</a>/<a href=/login>авторизації</a> на платформі.</div></div></div>
</div>
</div>
<div class="vert vert-1" data-id="block-v1:Profosvita+CS-M213+2023+type@problem+block@478cf2b03be54b009c17caf7f478adf2">
<div class="xblock xblock-public_view xblock-public_view-problem xmodule_display xmodule_ProblemBlock" data-course-id="course-v1:Profosvita+CS-M213+2023" data-block-type="problem" data-usage-id="block-v1:Profosvita+CS-M213+2023+type@problem+block@478cf2b03be54b009c17caf7f478adf2" data-request-token="344ee538224111f09d7d6e64c045cccd" data-graded="False" data-has-score="True">
<div class="page-banner"><div class="alert alert-warning"><span class="icon icon-alert fa fa fa-warning" aria-hidden="true"></span><div class="message-content">Питання 2 доступне для перегляду та виконання після <a href=/register>реєстрації</a>/<a href=/login>авторизації</a> на платформі.</div></div></div>
</div>
</div>
<div class="vert vert-2" data-id="block-v1:Profosvita+CS-M213+2023+type@problem+block@1c942833a6594bea9d48afb954c0e6fc">
<div class="xblock xblock-public_view xblock-public_view-problem xmodule_display xmodule_ProblemBlock" data-course-id="course-v1:Profosvita+CS-M213+2023" data-block-type="problem" data-usage-id="block-v1:Profosvita+CS-M213+2023+type@problem+block@1c942833a6594bea9d48afb954c0e6fc" data-request-token="344ee538224111f09d7d6e64c045cccd" data-graded="False" data-has-score="True">
<div class="page-banner"><div class="alert alert-warning"><span class="icon icon-alert fa fa fa-warning" aria-hidden="true"></span><div class="message-content">Питання 3 доступне для перегляду та виконання після <a href=/register>реєстрації</a>/<a href=/login>авторизації</a> на платформі.</div></div></div>
</div>
</div>
</div>
<script type="text/javascript">
(function (require) {
require(['/static/js/dateutil_factory.762fd6ff462b.js?raw'], function () {
require(['js/dateutil_factory'], function (DateUtilFactory) {
DateUtilFactory.transform('.localized-datetime');
});
});
}).call(this, require || RequireJS.require);
</script>
<script>
function emit_event(message) {
parent.postMessage(message, '*');
}
</script>
</div>
Завершення тесту
У вас залишилися невиконані завдання. Ви впевнені, що хочете завершити тест?
Тестування завершено.
Ви завершили тестування з розділу
"Тема 9. Зовнішні та тимчасові електропроводки"
© Всі права захищено